Yodify DEC Brand Library
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch
Brand: Kayden InstrumentsThe Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter features a precision-welded, highly accurate stainless steel sensor. Alarms and trip points are field-configurable for flow, temperature (high or low), hysteresis, time delay, and more.
Ideal for liquids, gases, and slurries in a clean or dirty process, the CLASSIC 810 is available in a wide range of thread sizes and insertion lengths. Kayden's electronic thermal dispersion flow and level switches have no moving parts to foul, clog, or stick, resulting in exceptional reliability and requiring little to no maintenance.
With no moving parts and minimal invasiveness, Kayden's thermal flow and level switches provide a highly repeatable, accurate, low-cost-of-ownership, long-life, and easy-to-install solution for demanding air, gas, liquid, and slurry applications.
All Kayden® CLASSIC® models feature a rugged flameproof enclosure with blind or glass lens covers. Kayden’s advanced digital electronics will streamline the way you monitor and control your process.
- Process Connections - Male NPT
- 1/2"
- 3/4"
- 1"
- 1-1/4"
- 1-1/2"
- 2"
- Adjustable Set Point Range
- 0 - 254 feet/s
- 0 - 77 meters/s
- Insertion 'U' Lengths
- 1.2" (3.0 cm)
- 2" (5.0 cm)
- 3" (7.5 cm)
- 4" (10.1 cm)
- 6" (15.2 cm)
- 9" (22.8 cm)
- 12" (30.4 cm)
- 18" (45.7 cm)
- Custom Lengths from 2.5" to 120" (6.0 cm to 305 cm) by 1/2" (1 cm) increments
- Input/Supply Power
- 12-24 Vdc & 120-240 Vac, 50-60 Hz
- Operating Pressure - Maximum
- CSA - Canadian Standards Association
- psi 3,480
- kPa 24,000
- bar 240
- CRN - Canadian Registration Number 0F22124.2C for 316/316L Stainless Steel
- psi 1,990
- kPa 13,721
- bar 137.2
- CSA - Canadian Standards Association
- Temperature Range - Sensor
- -55° to 200° C
- -67° to 392° F
- Local Enclosure
- Aluminum
- 1" Female NPT
- Hazardous Areas
- Local Enclosure Cover
- Blind or Glass Lens
- Hazardous Areas
- Wetted Materials
- 316/316L Stainless Steel
- Titanium
- Hastelloy C-276
- Outputs/Communications
- Two Independent Relays - SPDT
- 4-20 mA
- Modbus
- Rated 120 Vac max, 30 Vdc max, 4 A max
- Approvals
- CSA
- CRN
- Single Seal
- NACE
- ASME BPVC Sec. VIII Div. 1
- NEMA 4, 4X, 6P, IP65/67
Specifications
Brand
Applications
- Flow
- Level
- Interface
Principle of Operation
- Thermal, Calorimetric
Sensor, Probe Style
- Insertion Threaded
Process Connection - Male NPT
- 1/2"
- 3/4"
- 1"
- 1-1/4"
- 1-1/2"
- 2"
Insertion 'U' Length
- 1.2" (3 cm)
- 2" (5 cm)
- 3" (7.5 cm)
- 4" (10.1 cm)
- 6" (15.2 cm)
- 9" (23 cm)
- 12" (30 cm)
- 18" (46 cm)
- Custom Lengths from 6.4 cm to 305 cm (in 1 cm increments)
- Custom Lengths from 2.5" to 120" (in 1/2" increments)
Wetted Materials
Operating Pressure - Sensor
Operating Temperature - Sensor
Sensor Construction
Operating Temperature - Electronics
Switch Point Range
Response Time
Accuracy
Switch Type
Input Power
Output
Communication
Approvals & Certifications
Electronics - Standard Features
Remote Control & Monitoring Software
Environmental Protection
Local Enclosure Conduit Connection
Local Enclosure & Cover Material
Local Enclosure Cover
Local Enclosure & Cover Finish
Remote Electronics Enclosure Cover
Remote Electronics Enclosure & Cover Finish
Storage Temperature
Documentation
Product Manuals
- Product Manual - Kayden Classic 800 Flow to Velocity Quick Reference Guide pdf 5.8 MB
- Product Manual - Kayden CLASSIC 800 Modbus Registers pdf 116 KB
- Product Manual - Kayden CLASSIC 800 Quick Setup Guide v5.6 pdf 1.5 MB
- Product Manual - Kayden CLASSIC 800, Feb 2025 pdf 17.4 MB
Application Considerations
- Application Consideration - Kayden Process Conditions pdf 430 KB
Application Notes
- Application Note - Kayden 4-20mA Analog Output pdf 815 KB
- Application Note - Kayden Acid Level Detection pdf 1,022 KB
- Application Note - Kayden Fail Safe pdf 801 KB
- Application Note - Kayden High Level Detection Holding Tank pdf 572 KB
- Application Note - Kayden Leak Detection pdf 1.2 MB
- Application Note - Kayden Monitoring Digester Flow pdf 410 KB
- Application Note - Kayden Oil Water Separation pdf 923 KB
- Application Note - Kayden Pulp and Paper Digester Tank pdf 810 KB
- Application Note - Kayden Pulp and Paper Skimmer Tank pdf 408 KB
- Application Note - Kayden Pump Monitoring and Protection pdf 898 KB
- Application Note - Kayden Pump Monitoring and Protection Remote pdf 880 KB
Catalogs
- Catalogs - Kayden CLASSIC 800 Brochure pdf 3.8 MB
- Catalogs & Brochures - Kayden CLASSIC 800 Series Features pdf 96 KB
- Catalogs & Brochures - Kayden CLASSIC 800 Series Overview pdf 304 KB
Certifications & Approvals
- Certifications & Approvals - Kayden 800 CLASSIC CSA 2023 pdf 155 KB
Datasheet
- Data Sheet - Kayden CLASSIC 800 Technical Specifications Sheet pdf 325 KB
- Data Sheet - Kayden CLASSIC 810 Threaded pdf 350 KB
Outline Drawings
- 2020 Outline Dimension Drawing - Drawing A - Kayden CLASSIC 810 - Local Enclosure 1/2" MNPT pdf 190 KB
- 2020 Outline Dimension Drawing - Drawing B - Kayden CLASSIC 810 - Local Enclosure 3/4" MNPT pdf 194 KB
- 2020 Outline Dimension Drawing - Drawing C - Kayden CLASSIC 810 - Local Enclosure 1" MNPT pdf 184 KB
- 2020 Outline Dimension Drawing - Drawing D - Kayden CLASSIC 810 - Local Enclosure 1-1/4" MNPT pdf 187 KB
- 2020 Outline Dimension Drawing - Drawing E - Kayden CLASSIC 810 - Local Enclosure 1-1/2" MNPT pdf 188 KB
- 2020 Outline Dimension Drawing - Drawing F - Kayden CLASSIC 810 - Local Enclosure 2" MNPT pdf 221 KB
- 2020 Outline Dimension Drawing - Drawing G - Kayden CLASSIC 810 - Remote Enclosure 1/2" MNPT pdf 952 KB
- 2020 Outline Dimension Drawing - Drawing H - Kayden CLASSIC 810 - Remote Enclosure 3/4" MNPT pdf 950 KB
- 2020 Outline Dimension Drawing - Drawing I - Kayden CLASSIC 810 - Remote Enclosure 1" MNPT pdf 949 KB
- 2020 Outline Dimension Drawing - Drawing J - Kayden CLASSIC 810 - Remote Enclosure 1-1/4" MNPT pdf 958 KB
- 2020 Outline Dimension Drawing - Drawing K - Kayden CLASSIC 810 - Remote Enclosure 1-1/2" MNPT pdf 963 KB
- 2020 Outline Dimension Drawing - Drawing L - Kayden CLASSIC 810 - Remote Enclosure 2" MNPT pdf 953 KB
- Legacy Outline Dimension Drawing - Drawing A - Kayden CLASSIC 810 - Local Enclosure 1/2" MNPT pdf 330 KB
- Legacy Outline Dimension Drawing - Drawing B - Kayden CLASSIC 810 - Local Enclosure 3/4" MNPT pdf 321 KB
- Legacy Outline Dimension Drawing - Drawing C - Kayden CLASSIC 810 - Local Enclosure 1" MNPT pdf 315 KB
- Legacy Outline Dimension Drawing - Drawing D - Kayden CLASSIC 810 - Local Enclosure 1-1/4" MNPT pdf 311 KB
- Legacy Outline Dimension Drawing - Drawing E - Kayden CLASSIC 810 - Local Enclosure 1-1/2" MNPT pdf 321 KB
- Legacy Outline Dimension Drawing - Drawing F - Kayden CLASSIC 810 - Local Enclosure 2" MNPT pdf 312 KB
- Legacy Outline Dimension Drawing - Drawing G - Kayden CLASSIC 810 - Remote Enclosure 1/2" MNPT pdf 738 KB
- Legacy Outline Dimension Drawing - Drawing H - Kayden CLASSIC 810 - Remote Enclosure 3/4" MNPT pdf 720 KB
- Legacy Outline Dimension Drawing - Drawing I - Kayden CLASSIC 810 - Remote Enclosure 1" MNPT pdf 721 KB
- Legacy Outline Dimension Drawing - Drawing J - Kayden CLASSIC 810 - Remote Enclosure 1-1/4" MNPT pdf 714 KB
- Legacy Outline Dimension Drawing - Drawing K - Kayden CLASSIC 810 - Remote Enclosure 1-1/2" MNPT pdf 718 KB
- Legacy Outline Dimension Drawing - Drawing L - Kayden CLASSIC 810 - Remote Enclosure 2" MNPT pdf 723 KB
Software
- Kayden RCMS Software Rev 7.2.0 zip 45.0 MB
Wiring Diagrams
- Wiring Diagrams - Kayden CLASSIC 800 Integral Electronics pdf 1.9 MB
- Wiring Diagrams - Kayden CLASSIC 800 Remote Electronics pdf 292 KB
Brand-Managed Distributed Enterprise Catalogs (DEC)
for Authorized Channel Partners
for Authorized Channel Partners
Book a DEC Demo