Web.Requests
Yodify DEC Brand Library
Micropilot FMR60B 80 GHz Radar Sensor

Micropilot FMR60B 80 GHz Radar Sensor

Brand: Endress+Hauser

Micropilot FMR60B is part of the new generation of 80 GHz radar sensors. It is used for continuous non-contact level measurement in simple liquid applications with small process connections.

Wizards guide users through commissioning, proof tests and verification of the devices and thus guarantee a simple operation. Heartbeat Technology offers verification and monitoring functions to identify anomalies for more safety and increased productivity.

Micropilot FMR60B is suitable for free-space applications up to 50 m and offers high beam focusing for vessels with many internal fittings.

  • Process connections: Threads and flanges
  • Temperature: –40° to +200° C (-40° to 392° F)
  • Pressure: –1 bis +20 bar (-14.5 to +290 psi)
  • Maximum measuring range: 50 m (164 ft)
  • Accuracy: ±1 mm (0.04 in)
  • W-band: 80 GHz
  • International explosion protection certificates, overfill prevention WHG, SIL, marine approval, 5- or 10-point factory calibration certificate
Features

Specifications

Characteristic / Application

  • For simple continuous non-contact level measurements in liquids, pastes, and slurries
  • Not influenced by changing media, temperature differences, gas phases or steam
  • For vessels with many internals

Specialities

  • Heartbeat Technology
  • SIL 2 according to IEC 61508
  • Bluetooth® commissioning
  • Operation and maintenance with SmartBlue App
  • HistoROM
  • RFID TAG for easy identification

Supply / Communication

  • 2-wire (HART/ PROFIBUS PA)
  • PROFINET with Ethernet-APL
  • Bluetooth® wireless technology

Frequency

  • W-Band (~80 GHz)

Accuracy

  • ± 1 mm (0.04 in)

Ambient Temperature

Process Temperature

Process Pressure / Max. Overpressure Limit

Main Wetted Parts

Process Connection

Max. Measurement Distance

Communication

Certificates / Approvals

Safety Approvals

Design Approvals

Hygienic Approvals

Marine Approval

Options

Application Limits

Documentation

Data Sheets

  • Micropilot FMR60B HART Free-space Radar Technical Information pdf 2.2 MB
  • Micropilot FMR60B PROFIBUS PA Technical Information pdf 2.1 MB
  • Micropilot FMR60B PROFINET over Ethernet-APL Free-space Technical Information radar pdf 2.6 MB

Installation Instructions

  • Cover, cover seal, cover securing screw Installation Instructions pdf 612 KB
  • Dummy plug M20×1.5 G½, NPT ½, NPT ¾ Installation Instructions pdf 538 KB
  • EA Cable gland M20x1.5 Installation Instructions pdf 1.2 MB
  • Ground terminal Installation Instructions pdf 466 KB
  • HAN7D plug, 90 deg, housing side HAN7D socket, cable side Installation Instructions pdf 496 KB
  • HistoROM Installation Instructions pdf 1.1 MB
  • Replacement of the sensor electronics Installation Instructions pdf 1.6 MB
  • Replacement of transmitter VU140 Installation Instructions pdf 727 KB

Operating Instructions

  • BA Micropilot FMR60B PROFIBUS PA Operating Instructions pdf 2.4 MB
  • BA Micropilot FMR60B PROFINET over Ethernet-APL Operating Instructions pdf 3.3 MB
  • Housing filters Operating Instructions pdf 436 KB
  • Housing Operating Instructions pdf 1.6 MB
  • M12 plug (housing side) Operating Instructions pdf 1.5 MB
  • Micropilot FMR60B Free-space radar HART Operating Instructions pdf 2.4 MB
  • Replacement of main electronics pdf 1.0 MB
  • Replacement of the connecting cables Operating Instructions pdf 1.2 MB
  • Segment display VU100/VU101 Graphical display VU112/ VU113 Operating Instructions pdf 596 KB
  • Sensor Operating Instructions pdf 1.7 MB
  • Terminal module Operating Instructions pdf 572 KB
Brand-Managed Distributed Enterprise Catalogs (DEC)
for Authorized Channel Partners
Book a DEC Demo
show more