Yodify DEC Brand Library
SX-SH Limit Switch Box Series
SX-SH Limit Switch Box Series
Brand: Soldo Controls - by RotorkHeavy-duty limit switch boxes, designed for hazardous areas, provide a visual and electrical remote position feedback on automated valves.
Available in die cast aluminum matching the Ex d IIB T6 standards.
The SX/SH is our solution reaching Ex d IIB T6 or Ex d IIB + H2 T6 requirements.
Thanks to spare pass through terminals, the three cable entries either metrics or imperial and different visual position indications, provide a highly customizable solution meeting a wide range of applications.
These including, but not limited to, the Oil and Gas, both onshore and off shore, and Petrochemical industries.
FeaturesSpecifications
Ambient Temperature Range
- -40° to 105° C (-40° to 221° F)
Applications
- Oil & Gas Applications (Both On-Shore & Off-Shore)
- Petrochemical Industry
Approvals & Certifications
- ATEX: Ex II 2 GD Ex d IIB T4/T5/T6 Gb (SX Series), Ex II 2 GD IIB + H₂ T4/T5/T6 Gb (SH Series) & Ex Tb IIIC T135/T100/T85° C Db
- CCOE: Ex II 2 GD Ex d IIB T4/T5/T6 Gb (SX Series), Ex II 2 GD IIB + H₂ T4/T5/T6 Gb (SH Series) & Ex Tb IIIC T135 / T100 / T85° C Db
- CE
- cULus Listed, Class I,/2 Div. 1, Class I,/2 Div. 2
- EAC: Ex II 2 GD Ex d IIB T4/T5/T6 Gb (SX Series), Ex II 2 GD IIB + H₂ T4/T5/T6 Gb (SH Series) & Ex Tb IIIC T135, T100, T85° C Db
- IEC Ex: Ex II 2 GD Ex d IIB T4/T5/T6 Gb (SX Series), Ex II 2 GD IIB + H₂ T4/T5/T6 Gb (SH Series) & Ex Tb IIIC T135, T100, T85° C Db
- INMETRO: Ex II 2 GD Ex d IIB T4/T5/T6 Gb (SX Series), Ex II 2 GD IIB + H₂ T4/T5/T6 Gb (SH Series) & Ex Tb IIIC T135/T100/T85° C Db
- NEPSI
- PESO
- SIL 3
- UL: Class I, Div. 1, Groups B, C, D Div. 2, Grade A, B, C, D & Class II, Div. 1, Groups E, F, G Div. 2, Groups F, G
Cable Entry
- 1/2" NPT
- 3/4" NPT
- M25 x 1,5
- M20 x 1.5
Cover Material
- Die Cast Aluminum
Current
Electrical Connectors
Electrical Contacts
Electrical Rating
Enclosure Finish
Enclosure, Body Material
Environmental Protection
Indication
Shaft Material
Supply Voltage
Switch Quantity
Switch Type
Temperature Range
Terminal Strip
Documentation
Brochure
- Soldo Product Overview Brochure pdf 16.0 MB
Certifications & Approvals
- ATEX II2GD Dust Proof pdf 217 KB
- ATEX II2GD Explosion Proof pdf 217 KB
- CCOE Explosion Proof pdf 855 KB
- EAC Hazardous Location pdf 4.4 MB
- EAC Normally Location Low Voltage CU TR 004 pdf 304 KB
- High Temperature 250°C/300°C pdf 456 KB
- IEC EX Dust Proof pdf 284 KB
- IEC EX Explosion Proof pdf 285 KB
- Soldo SIL Certificate pdf 903 KB
- UL Explosion Proof pdf 184 KB
- UL No Spark pdf 181 KB
Dimensional Drawing
- SX Dimensional Drawing .PDF pdf 424 KB
Brand-Managed Distributed Enterprise Catalogs (DEC)
for Authorized Channel Partners
for Authorized Channel Partners